Product center
Product name: PDU Lightning Strip
Product number:
2019-07-25 Product time: 2019-07-25
PDU lightning protection strips are mainly suitable for lightning protection (over-voltage) protection of electronic and electrical equipment in low-voltage AC power (220V) systems, such as computers, communication equipment, high-end audio, film and television equipment, precision instruments, and meters.

product description

PDU Lightning Strip

■ Model description

-CP / 6 DIC -CP / 6

DIC: Cerec (Brand)

CP: Lightning protection socket

6: six socket, PDU: rack socket

■ Product use

DIC lightning protection sockets are mainly suitable for lightning protection (overvoltage) protection of electronic and electrical equipment in low-voltage AC power (220V) systems, such as computers, communication equipment, high-end audio, film and television equipment, precision instruments, meters, etc.

■ Product Features

● The product is suitable for over-voltage protection at the end of the equipment.

● Low residual voltage and large discharge current.

● Common mode, differential mode * protection.

● Energy saving and environmental protection.

新国标6口;机架式6口、10A、1U塑壳 )内置10A过载保护器,具备短路保护功能,不会因为超负荷而发生火灾。 ● Lightning protection socket ( new national standard 6-port; rack-type 6-port, 10A, 1U plastic shell ) built-in 10A overload protector, with short-circuit protection function, will not cause fire due to overload.

■ Technical parameters

name

model

specification

Nominal put

Electric current

In (kA,

8 / 20μs)

Max put

Electric current

Imax (kA,

8 / 20μs)

Voltage protection

Protection level

Up (kV)

Rated

Current

(A)

response

time

A (ns) t A (ns)

Rated worker

Working voltage

AC ) Un (V AC )

Most hold

Continue work

Voltage

AC ) Uc (V AC )

Leakage current

1mA 0.75U 1mA

(μA)

jobs

temperature

(℃)

Lightning protection socket

DIC-CP / 4

New national standard 4

5

10

1.2

10

≤25

220

275

≤20

-40

~

+85

DIC-CP / 6

New national standard 6

5

10

1.2

10

DIC-CP / PDU

6-port, 10A, 1U plastic case

5

10

1.2

10

DIC-CP / PDU

Rack-mount 6-port, 10A, 1U

5

10

1.2

10

PDU DIC-CP / PDU

Rack-mount 6-port, 10A, 1.5U

5

10

1.2

10

DIC-CP / PDU

Rack-mount 6-port, 16A, 1.5U

5

10

1.2

16

DIC-CP / PDU

Rack-mount 8-port, 10A, 1.5U

5

10

1.2

10

DIC-CP / PDU

Rack-mount 8-port, 16A, 1.5U

5

10

1.2

16

■ Installation instructions

防雷插座( 新国标4口 新国标6口 ):接通电源并打开电源开关后,电源指示灯亮,则表示电源正常接通;工作指示灯亮,则表示防雷组件正常工作;反之,插座不可使用,应及时维修或更换。 Lightning protection socket ( 4 ports for the new national standard; 6 ports for the new national standard ): After the power is turned on and the power switch is turned on, the power indicator is on, indicating that the power supply is normally connected; the work indicator is on, indicating that the lightning protection component is working normally; otherwise, The socket is not usable and should be repaired or replaced in a timely manner.

:接通电源并打开电源开关后,电源指示灯亮(开关带电源指示),则表示电源正常接通和防雷组件正常工作;反之,插座不可使用,应及时维修或更换。 ● Lightning-proof socket : After the power is turned on and the power switch is turned on, the power indicator is on (the switch has a power indicator), which indicates that the power supply is normally connected and the lightning-proof components are working normally; otherwise, the socket is not available and should be repaired or replaced in time.

:接通电源并打开电源开关后,电源指示灯亮(开关带电源指示),则表示电源正常接通;工作指示灯亮,则表示防雷组件正常工作;反之,插座不可使用,应及时维修或更换。 ● Lightning protection socket : After turning on the power and turning on the power switch, the power indicator light is on (the switch has a power indicator), which indicates that the power supply is normally connected; the work indicator light is on, which indicates that the lightning protection component is working normally; otherwise, the socket cannot be used. Repair or replace in time.

● The load current cannot exceed the rated current of the lightning protection socket.

新国标6口;机架式6口、10A、1U塑壳 :当负载功率超过插座的额定功率或短路时,防雷插座会自动断开电源,以确保用电安全。 ● Lightning protection socket with overload protection ( new national standard 6-port; rack-type 6-port, 10A, 1U plastic case ) : When the load power exceeds the rated power of the socket or short circuit, the lightning protection socket will automatically disconnect the power to ensure Electrical Safety. If you need to use it again, just press the reset button.

● The ground terminal of the lightning protection socket is connected to the E terminal of the ground wire on the plug.

● When the ground terminal of the socket connected to the lightning protection socket meets the grounding requirements, you can directly insert the plug of the lightning protection socket; otherwise, you must connect the grounding terminal of the lightning protection socket to the ground network before using it. In order to achieve better lightning protection, it is recommended that the ground terminal of the lightning protection socket be reliably connected to the ground network.

■ Product size chart

1.New national standard 4 mouths

2.New national standard 6

3.Rack-type 6-port, 10A, 1U plastic case

4.Rack-type 6-port, 10A, 1U

5.Rack type 6 port, 10A, 1.5U

6.Rack type 6 port, 16A, 1.5U

7.Rack-type 8-port, 10A, 1.5U

8.Rack-type 8-port, 16A, 1.5U

Related Products

Message box

  • product:

  • Message content:

  • Your unit:

  • Your Name:

  • contact number:

  • Common mailbox:

  • Address:

  • province:

  • Verification code:

    Please enter the calculation result (fill in Arabic numerals), such as: three plus four = 7
online service
Back to top
Scan to visit the mobile station Scan to visit the mobile station
Visit mobile station